The sensor module FCX-MLXX is a complete solution for measuring oxygen within the range of 0.1 - 25%. The sensor and electronics are integrated on one board. The module takes the signal directly from the sensor and amplifies it into a nonlinear but logarithmic 4-20 mA output.
Specifications
- Measurement Ranges: 0.1 - 25%
- Supply: 24 VDC nominal (7 - 28 VDC)
- Current supply: 200 mA typical
- Power consumption: 3W
- Output: adjustable 4-20 mA
- Accuracy: ±0.5% FS
- Stability: ±0.5% FS/Year
- Repeatability: ±1% of reading
- Response time: less than 30 sec
- Gas temperature: -10 to 50°C
- Operating temperature: -20 to 70°;C
- Humidity: 98% noncondensing
- Dimensions: 75L X 40W X 28H mm
- Weight: 100g