The MB-LPS1-01 Series of low pressure sensors measure differential air (or other non-corrosive gas) pressure, inferring differential pressure from nano-liters per second gas-flow through an integrated airflow channel having high flow impedance. The transducer is a MEMS-based thermo-anemometer on a monolithic silicon chip. Rejuster™ technology combined with CMOS circuitry provides on-chip integrated analog only compensation and conditioning electronics.
Rejustor™ technology produces electrically adjustable resistors and passive temperature compensation devices that are non-volatile (i.e. does not need power to hold its adjustment), and can be adjusted permanently, or, if required, re-adjusted at a later date. New 3V supply model now released!
Applications for the MB-LPS1-01 include HVAC, medical CPAP airflow sensing, fume hoods, biological safety cabinets, critical containment enclosures, leak detection, value-added transducers/transmitters and more.
| Part # (R or N at end = Ratiometric or Non-ratiometric) | Measurement Range in Full Scale |
|---|---|
| MB-LPS1-01-010B5N or R | ±25Pa , ±0.1"H2O, ±0.0036PSI |
| MB-LPS1-01-010U5N or R | 0-25Pa, 0-0.1"H2O, 0-0.0036PSI |
| MB-LPS1-01-020B5N or R | ±50Pa , ±0.2"H2O, ±0.0072PSI |
| MB-LPS1-01-020U5N or R | 0-50Pa , 0-0.2"H2O, 0-0.0072 PSI |
| MB-LPS1-01-100B5N or R | ±250Pa , ±1.0"H2O, ±0.036 PSI |
| MB-LPS1-01-100U5N or R | 0-250Pa , 0-1.0"H2O, 0-0.036 PSI |
| MB-LPS1-01-200B5N or R | ±500Pa , ±2.0"H2O, ±0.072 PSI |
| MB-LPS1-01-200U5N or R | 0-500Pa , 0-2.0"H2O, 0-0.072 PSI |

Servoflo Corporation
75 Allen Street
Lexington, MA 02421
Phone: (781) 862-9572
Fax: (781) 862-9244